Clatronic BS 1294 User Manual Page: 33

Clatronic BS 1294 User Manual Page: 33
33
Motor protection lter (inlet lter)
The inlet lter is located in the dust container space. The lter
sits vertically in the rear part of the dust housing. Do not remove
the rubber seal! Pull the lter (black foam) out to the front.
Clean the motor protection after every approx. 10th emptying of
the dust container.
When required, you can clean
the lter with warm water
without any additions. Reinsert
it only after it is completely dry.
Outlet lter (7)
The appliance is also equipped with an outlet lter. It is located
on the rear of the device under the parking aid.
We recommend that you clean the lter every 6 months to
assure correct functioning.
1. Push the lever to the left
and remove the ventilation
grid.
2. Remove the lter insert
and clean it as described
above.
3. Place the completely dry lter back into the ventilation grille.
4. Put the ventilation grille back on the appliance. Observe the
guide lugs. The ventilation grid must engage audibly.
Cleaning
WARNING:
Before cleaning remove the mains lead from the socket.
Under no circumstances should you immerse the device in water
for cleaning purposes. Otherwise this might result in an electric
shock or re.
CAUTION:
Do not use a wire brush or any abrasive items.
Do not use any acidic or abrasive detergents.
Clean the housing with a soft, dry cloth without additives.
Storage
Let the device cool down completely.
Wind the cable completely.
Please insert the hook of the oor nozzle into the parking
assistant on the rear of the device.
When you place the appliance vertically: Hang the hook of
the accessory holder (on the suction tube) into the parking
aid on the underside of the appliance.
Troubleshooting
The Device Does Not Work.
Remedy:
Check the connection to the mains.
Check the position of the switch.
The device does not suck up anything.
Possible Cause:
The dust collector is full.
Remedy:
Empty the dust collector.
or
Possible Cause:
The lters are dirty.
Remedy:
Clean the components.
or
Possible Cause:
There is a foreign body in the suction tube or the nozzle.
Remedy:
Check the accessories for foreign bodies.
Technical Data
Model:..........................................................................BS 1294
Power supply:....................................... 220 - 240 V~, 50 / 60 Hz
Protection class: ......................................................................
Net weight: ........................................................approx. 4.70 kg
The right to make technical and design modications in the
course of continuous product development remains reserved.