Hunter Industries WFS-T Owners Manual Page: 10

10
INSTALLING THE WFS SENSOR INTO THE FCT FITTING
The FCT tee fitting comes with a plug that allows for installation of
the FCT into the irrigation system prior to installing the sensor. This
allows the FCT tee to be installed separately from the sensor and
prevents damage during installation of the body.
NOTE: Do not attempt to remove the sensor plug or sensor
while the system is under pressure.
To install the sensor into the body:
1.
Turn the system pressure o.
2.
Unscrew the cap from the top of the FCT (gure 1).
3.
Use pliers or a screwdriver and carefully pry the plug from the FCT tee.
Save plug for winterization use.
4.
Insert the sensor into the FCT. The sensor has a at side that engages
on the inside of the sensor body (gure 2).
5. Hand-tighten the WFS sensor cap. (gure 3).
Figure 1
Figure 1 Figure 3
Figure 2
Figure 2
NOTE: Never glue the WFS sensor into the
fitting! The threaded cap is designed to seal
under pressure.